Context
Soundproofing of a heat pump
Reduction of heat pump noise through the soundproofing of the unit in a private residential building context.
Heat pump noise is not usually one of the variables that is carefully considered when choosing to adopt this heating and cooling system, both in residential and industrial contexts.
In this specific case, the issue concerned a private home located within a historic city center, where the heat pump had been installed in the garden.
As mentioned, especially in recent years, the use of a single system capable of both heating and cooling indoor environments has become increasingly widespread. However, the real question is: how much noise does a unit of this size actually produce?
In this specific case, since the building is located within a historic center, the acoustic zoning of the territory places the area in Class IV, with 60 dB(A) for the daytime reference period and 50 dB(A) for the nighttime reference period.
Summary table of the acoustic limits provided by current legislation
Land use classification (Presidential Decree 14/11/1997, Art. 3)
Reference time periods
Immission limit values – Leq in dB(A) (Art. 2)
Land use classification (Presidential Decree 14/11/1997, Art. 3)
Reference time periods
Solution
2Zeta’s acoustic measurement survey
The acoustic measurements carried out during the nighttime period recorded a noise level of 67 dB(A) at 1 m from the unit. The objective of the heat pump soundproofing measures was to reduce the noise level by 17 dB(A) at 1 m from the unit.
The proposed soundproofing intervention, within the context of environmental acoustic solutions, started from the analysis of the heat pump itself, taking into account pressure losses and air flow rate, as it was essential to ensure the correct functioning of the unit.
We therefore designed a dissipative baffle silencer installed above the exhaust fans.
The silencer consists of sound-absorbing and sound-insulating panels, with internal sound-absorbing elements. Their spacing and length were calculated based on pressure losses and airflow rate, without neglecting the required acoustic attenuation to be achieved.
Results