2 Zeta is a team of 20 people who, since 1989, designs, manufactures and installs soundproofing systems for various noise sources in the industrial, environmental, civil and energy sectors.
Company address

Context

Construction of a soundproof enclosure for a refrigeration system.

In general terms, anything that moves in contact with air generates pressure variations in it, which can potentially create noise of varying intensity, leading to different issues.

This concept can obviously also be applied to a refrigeration system.

Therefore, it is essential to address the issue efficiently and effectively when the noise becomes excessive, as in this case.

Solution

2Zeta’s solution:

an outdoor soundproof enclosure with an evaporative cooling tower. The soundproof box houses the absorber inside, while the evaporative cooling tower is installed on the roof. The structural design of this steel soundproof enclosure was carried out in accordance with the NTC 2018 standards, taking into account the static load of the evaporative cooling tower and the piping system.

Structural parameters

Use classII
Nominal service life (years)50
Use coefficient1.0
Reference period (years)50.0

The actions that the structure may be subjected to were analysed through load modelling and the schematisation of load cases.

The methods and criteria adopted to assess the safety of the enclosure with respect to potential failure scenarios, as well as the results of the performed evaluations, were defined accordingly.

In general terms, in addition to strength and displacement checks, verifications were also carried out with respect to instability phenomena—both local and global—as well as fatigue, ductility, and degradation.

The sound power level of the equipment as a whole was 85 dB(A), while the target to be achieved was 55 dB(A).

Therefore, 50 mm thick sound-absorbing panels were applied to the enclosure, fixed to the internal structure.

One side of the soundproof enclosure was designed with a fully openable 4-metre-high panel system, allowing easy access for maintenance vehicles to the absorber system.

In addition, a ventilation system was designed and implemented to ensure the proper operation of the plant, through air intakes with dissipative baffles sized according to the airflow rate of the absorber and the systems installed inside the enclosure, as well as the required acoustic performance targets.

Both the guardrails and the stairs included in the design of this soundproof enclosure were manufactured in compliance with standards UNI EN ISO 14122-1, 14122-2, 14122-3, and 14122-4 of Legislative Decree 81/08.

Results

Results

Following the soundproofing intervention, we were able to reduce the noise by 30 dB(A).

-30dB