2 Zeta

Company
2 Zeta is a team of 20 people who, since 1989, designs, manufactures and installs soundproofing systems for various noise sources in the industrial, environmental, civil and energy sectors.
Company address

Context

Environmental acoustic barrier

The subject of the intervention is an acoustic barrier designed to contain environmental disturbances generated by technological systems serving the Novara Hospital.

The dimensional and functional characteristics required to achieve the noise reduction targets were defined by the Qualified Acoustic Technician appointed by the client, while the general technical and aesthetic features were proposed by us in order to adapt and integrate the structure into its installation context, namely the historic city center.

The close collaboration and synergy among all parties involved ensured a successful installation in a remarkably short timeframe.

Solution

2 Zeta’s solution: acoustic barrier

The intervention consists in the construction of an acoustic barrier in the historic city center with dimensions: L35 x H5 meters.

Given the significant size of the barrier and the resulting exposure to high wind loads, particular attention was given to the structural design.

Our engineers carried out a thorough design process, ensuring compliance with the current applicable technical standards. This work was then reviewed and approved by the client’s technical office.

The result is a tubular frame structural system, securely anchored to the existing structures through mechanical fastening systems.

The enclosure is completed with our panels, 100 mm thick and featuring high acoustic performance, finished in light ivory paint with a 30 gloss finish, which integrates well into the surrounding context.

Fire reaction Euroclass A1 according to EN 13501-1.

Acoustic characteristics

Acoustic performance rating indices

DLα,NRD = 12 dB – Rating index of sound absorption in a reverberation chamber according to standard UNI EN 1793-1:2017.

Test report no. 001-2020-BAR1 by Z Lab Srl
DLR = 33 dB – Rating index of airborne sound insulation performance according to standard UNI EN 1793-2:2018.

Test report no. 002-2020-BAR2 by Z Lab Srl
Equivalent value corresponding to RW = 40 dB according to standard UNI EN ISO 717-1.

Contacts

We build silence
tailored to measure